SATE system
Fixing plugs
Wide range of sizes depending on the thickness of the insulation board.

INSTRUCTIONS FOR USE
The fixings are placed on the perimeter about 150 mm from the edge and in the centre of the boards, and the type of plug is chosen depending on the substrate and the thickness of the insulation board.
Surface:
Drill with a 10 mm drill bit through the insulation board and ensure a minimum anchorage depth of 50 mm to the substrate. Insert the dowel into the hole and anchor by tapping by pressing the circular head of the dowel so that it is 1 to 2 mm below the surface of the board.
Insulation:
Taking the hole made as the centre and attaching the appropriate cutting attachment to the drill, a cavity is made inside the insulating plate. The plug is tapped into the cavity and the appropriate insulating plug is then fitted.
Packing List
| GTIN-13 | Item |
|---|---|
| 8437021710649 | MECHANICAL FIXING DOWELS 10 x 60 mm |
| 8437021710656 | MECHANICAL FIXING DOWELS 10 x 70 mm |
| 8437021710663 | MECHANICAL FIXING DOWELS 10 x 90 mm |
| 8437021710670 | MECHANICAL FIXING DOWELS 10 x 110 mm |
| 8437021710687 | MECHANICAL FIXING DOWELS 10 x 120 mm |
| 8437021710694 | MECHANICAL FIXING DOWELS 10 x 140 mm |
| 8437021710700 | MECHANICAL FIXING DOWELS 10 x 160 mm |
| 8437021710717 | MECHANICAL FIXING DOWELS 10 x 180 mm |
| 8437021710724 | MECHANICAL FIXING DOWELS 10 x 200 mm |
| 8437021710731 | MECHANICAL FIXING DOWELS 10 x 220 mm |
| 8437021710748 | MECHANICAL FIXING DOWELS 10 x 260 mm |